How to Bypass Co Sensor on Generator? [6 Step Guide]

How to Bypass Co Sensor on Generator

Carbon monoxide (CO) sensors are critical safety components in modern generators, designed to prevent harmful exposure to dangerous gases.

However, there are situations where a CO sensor may malfunction, leading to a need for troubleshooting or temporary bypassing.

This article provides an in-depth guide on how to safely bypass a CO sensor on a generator, along with important considerations to ensure safety and compliance.

What Is a Co Sensor on Generator?

A carbon monoxide (CO) sensor on a generator is a safety device that detects carbon monoxide gas, which is a colorless, odorless, and dangerous gas produced when fuel burns incompletely.

Generators release CO during operation, and if the area is not well-ventilated, the gas can build up to unsafe levels. The CO sensor is built into the generator to check the air for CO and alert users when the levels become unsafe.

Many modern generators also have an automatic shut-off feature that turns off the machine if CO levels get too high, preventing further danger.

This sensor is especially important because using generators indoors or in poorly ventilated spaces can lead to carbon monoxide poisoning.

CO sensors help keep users safe by ensuring the generator is operated under safe conditions. Some generators also have alarms or screens to warn users before CO levels become critical.

Manufacturers include these sensors to meet safety standards and raise awareness about the dangers of CO, making them an essential part of generators used for backup power, outdoor activities, or construction work.

Precautions Before Bypassing a CO Sensor

Bypassing a CO sensor is not a recommended long-term solution and should only be considered when absolutely necessary. Follow these safety precautions:

  • Ensure Proper Ventilation: Operate the generator in a well-ventilated area to reduce CO buildup.
  • Use CO Detectors: Install additional portable CO detectors to monitor gas levels.
  • Consult Manufacturer Guidelines: Refer to your generator’s manual for specific troubleshooting advice.
  • Temporary Solution Only: Plan to repair or replace the faulty sensor as soon as possible.

Tools Required for the Process

To bypass a CO sensor, you may need the following tools:

  • Screwdrivers (flathead and Phillips)
  • Wire cutters and strippers
  • Electrical tape or heat-shrink tubing
  • Multimeter (optional, for testing electrical connections)

Step-by-Step Guide to Bypass a CO Sensor

1. Disconnect the Generator from Power Sources

  • Turn off the generator and allow it to cool.
  • Disconnect it from any power outlets or connected appliances.
  • Remove the spark plug to prevent accidental startup during the procedure.

2. Locate the CO Sensor

  • Refer to the user manual for the sensor’s exact location.
  • Typically, the CO sensor is housed near the exhaust or engine compartment.

3. Access the Sensor Wiring

  • Remove the generator’s protective casing using appropriate screwdrivers.
  • Identify the wires connected to the CO sensor. These are usually color-coded for easy identification.

4. Disconnect the Sensor

  • Use the multimeter to test the sensor for continuity. If it’s faulty, proceed with bypassing.
  • Cut the wires leading to the sensor using wire cutters. Leave enough length for reconnection if necessary.

5. Create a Bypass Connection

  • Strip the ends of the wires previously connected to the sensor.
  • Connect the wires together directly to close the circuit. Use electrical tape or heat-shrink tubing to insulate the connection.

6. Reassemble the Generator

  • Reattach the protective casing securely.
  • Reinstall the spark plug and reconnect any detached components.
  • Test the generator to ensure it operates without shutting down.

Why Would You Bypass a CO Sensor?

If the carbon monoxide (CO) sensor on your generator is faulty, it may beep constantly or cause the generator to start and shut off after a few seconds. In such cases, you might need to bypass the CO sensor temporarily to test if the generator works properly without it.

If the generator runs fine after bypassing the sensor, the CO sensor likely needs replacement.

Important Safety Note
The CO sensor is crucial for your safety, especially if you’re using the generator in a closed area. Don’t bypass it unless you suspect it’s causing issues. If you do bypass it, make sure it’s only temporary.

Do Generators Need a CO Sensor?


Yes, having a CO sensor is very important. If your generator doesn’t come with one, consider buying a separate sensor—especially if the generator is near your RV or house.

Safety Tips Before Bypassing the CO Sensor

  • Move the generator to a well-ventilated area, away from flammable items.
  • Let the generator cool down before handling it.
  • Read the user manual to understand the process.
  • Replace the CO sensor once you identify the problem.
  • Operating a generator without a CO sensor may result in fines, so check local regulations.

Do Whole-House Generators Emit Carbon Monoxide?


Yes, all generators, including standby or whole-house models, produce carbon monoxide. Follow safety guidelines carefully when installing or operating any generator.

Final Thoughts

Bypassing the CO sensor can help you identify if it’s causing problems, like constant beeping or unexpected shutdowns. However, once confirmed, you should replace the faulty sensor.

A CO sensor is a critical safety device—it could save your life if the generator is used in enclosed spaces. As a rule of thumb, always use a separate CO sensor for added safety and place your generator at least 15 feet away from living spaces.

If you have any questions about bypassing a CO sensor, feel free to ask in the comments!

FAQs

What is a CO sensor on a generator?

A CO (carbon monoxide) sensor on a generator is a safety feature designed to detect dangerous levels of carbon monoxide gas. When CO levels become too high, the sensor triggers an alarm and can automatically shut off the generator to prevent CO poisoning.

What tools are needed to bypass the CO sensor?

The tools needed to bypass the CO sensor may include a bypass plug, electrical tape, a resistor, and basic electrical tools such as screwdrivers and wire cutters. The specific tools required will depend on the method used to bypass the sensor.


What are the legal consequences of bypassing the CO sensor?

Bypassing the CO sensor can lead to legal consequences, especially if it results in harm or property damage. It is important to follow safety guidelines and seek professional assistance when dealing with generator issues.

Can electrical tape be used to bypass the CO sensor?

Some users have suggested using electrical tape to cover the CO sensor as a quick fix to prevent it from detecting CO levels. However, this method is not recommended as it does not address the underlying issue and can be unsafe.

What should be done after bypassing the CO sensor?

After bypassing the CO sensor, it is important to test the generator to ensure it is functioning properly. If the sensor was the issue, the generator should operate normally. However, it is essential to seek professional assistance for sensor repair or replacement to ensure safe operation in the long run.

How can a bypass plug be used to bypass the CO sensor?

A bypass plug is designed to fit into the sensor socket, effectively bypassing the CO detector. This plug can be found in many hardware stores or online marketplaces. However, it should only be used as a short-term fix, and the generator should be operated in open-air environments to avoid the risk of carbon monoxide poisoning.

What are the risks of bypassing the CO sensor?

Bypassing the CO sensor eliminates a critical safety feature, which can expose users to the risk of carbon monoxide poisoning. It is essential to operate the generator in well-ventilated areas and seek professional assistance for sensor repair or replacement as soon as possible.

Why might someone need to bypass the CO sensor on a generator?

Someone might need to bypass the CO sensor if it is faulty and causing the generator to shut down unnecessarily, even in safe conditions. This can be a temporary solution while awaiting repair or replacement of the sensor.